medrxiv; 2022.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2022.01.28.22269783

ABSTRACT

Introduction: Rapid antigen detection tests (RDT) are suitable for large-scale testing for SARS-CoV-2 among the population and recent studies have shown that self-testing with RDT in the general population is feasible and yields acceptable sensitivities with high specificity. We aimed to determine the accuracy of two different RDT, with two different sample collection methods for one of the RDT among healthcare workers (HCW). Secondary objectives were to determine the accuracy of RDT using a viral load cut-off as proxy of infectiousness and to identify predictors for a false negative RDT. Methods: Centers that participated were secondary care hospitals, academic teaching hospitals, and long-term care facilities. All HCW that met inclusion criteria were asked to perform a RDT self-test next to a regular SARS-CoV-2 nucleic acid amplification test (NAAT). Three study groups were created. Study group 1; Veritor System, Becton Dickinson, Franklin Lakes, USA (BD-RDT) with combined oropharyngeal - mid-turbinate nasal sampling, group 2; BD-RDT with mid-turbinate nasal sampling only and group 3; SD Biosensor SARS-CoV-2 Rapid Antigen Test, Roche, Basel, Switzerland (Roche-RDT) with combined oropharyngeal - mid-turbinate nasal sampling. RDT accuracy was calculated using NAAT as reference standard. For samples processed in the cobas(R) 6800/8800 platform (Roche Diagnostics, Basel, Switzerland), established cycle threshold values (Ct-values) could be converted into viral loads. A viral load cut-off of [≥]5.2 log10 SARS-CoV-2 E gene copies/ml was used as proxy of infectiousness. Logistic regression analysis was performed to identify predictors for a false negative RDT. Results: In total, 7,196 HCW were included. Calculated sensitivities were 61.5% (95%CI 56.6%-66.3%), 50.3% (95%CI 42.8%-57.7%) and 74.2% (95%CI 66.4%-80.9%) for study groups 1, 2 and 3, respectively. After application of a viral load cut-off as a proxy for infectiousness for samples processed in the cobas(R) 6800/8800 platform sensitivities increased to 82.2% (95%CI 76.6-86.9%), 61.9% (95%CI 48.8%-73.9%) and 90.2% (95%CI 76.9%-97.3%) for group 1, group 2 and group 3, respectively. Multivariable regression analysis showed that use of Roche-RDT (p <0.01), combined oropharyngeal - mid-turbinate nasal sampling (p <0.05) and the presence of COVID-19 like symptoms at the time of testing (p <0.01) significantly reduced the likeliness of a false-negative RDT result. Conclusion: SARS-CoV-2 RDT has proven able to identify infectious individuals, especially when upper respiratory specimen is collected through combined oropharyngeal - mid-turbinate sampling. Reliability of self-testing with RDT among HCW seems to depend on the type of RDT, the sampling method and the presence of COVID-19 like symptoms at the time of testing.


Subject(s)
COVID-19
2.
medrxiv; 2021.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2021.02.21.21252153

ABSTRACT

IntroductionSelf-testing for COVID-19 infection with lateral flow assay SARS-CoV-2 rapid antigen detection tests (RDT), provides rapid results and could enable frequent and extensive testing in the community, thereby improving the control of SARS-CoV-2. The objective of this study is to evaluate the performance of self-testing using RDT without assistance. MethodsParticipants visiting a municipal SARS-CoV-2 testing centre, received self-testing kits containing either the BD Veritor System (BD RDT) or Roche SARS-CoV-2 antigen detection test (Roche RDT). Oro-nasopharyngeal swabs were collected from the participants for qRT-PCR testing. As a proxy for contagiousness, viral culture was performed on a selection of qRT-PCR positive samples to determine the Ct-value at which the chance of a positive culture was dropping below 0.5 (Ct-value cut-off). Sensitivity and specificity of self-testing were compared to qRT-PCR with a Ct-value below the Ct value cut-off. Determinants independently associated with a false-negative self-test result were determined. ResultsA total of 3,215 participants were included (BD RDT n=1604; Roche RDT n=1611). Sensitivity and specificity of self-testing compared to the qRT-PCR results with Ct-value below the Ct-value cut-off was 78.0% (95% CI:72.5-82.8) and 99.4% (95%CI: 99.0-99.6) respectively. Determinants independently associated with a false-negative self-testing results were: higher age, low viral load and finding self-testing difficult. DiscussionSelf-testing using currently available RDTs has a high specificity and relatively high sensitivity to identify individuals with a high probability of contagiousness. The performance of two tests were comparable. This application has the potential for frequent and extensive testing which may be an aid to lift restrictions to society while controlling the spread of SARS-CoV-2.


Subject(s)
COVID-19
SELECTION OF CITATIONS
SEARCH DETAIL